Header logo is


2017


no image
Editorial for the Special Issue on Microdevices and Microsystems for Cell Manipulation

Hu, W., Ohta, A. T.

8, Multidisciplinary Digital Publishing Institute, September 2017 (misc)

pi

DOI [BibTex]

2017


DOI [BibTex]


no image
Swimming in low reynolds numbers using planar and helical flagellar waves

Khalil, I. S. M., Tabak, A. F., Seif, M. A., Klingner, A., Adel, B., Sitti, M.

In International Conference on Intelligent Robots and Systems (IROS) 2017, pages: 1907-1912, International Conference on Intelligent Robots and Systems, September 2017 (inproceedings)

Abstract
In travelling towards the oviducts, sperm cells undergo transitions between planar to helical flagellar propulsion by a beating tail based on the viscosity of the environment. In this work, we aim to model and mimic this behaviour in low Reynolds number fluids using externally actuated soft robotic sperms. We numerically investigate the effects of transition between planar to helical flagellar propulsion on the swimming characteristics of the robotic sperm using a model based on resistive-force theory to study the role of viscous forces on its flexible tail. Experimental results are obtained using robots that contain magnetic particles within the polymer matrix of its head and an ultra-thin flexible tail. The planar and helical flagellar propulsion are achieved using in-plane and out-of-plane uniform fields with sinusoidally varying components, respectively. We experimentally show that the swimming speed of the robotic sperm increases by a factor of 1.4 (fluid viscosity 5 Pa.s) when it undergoes a controlled transition between planar to helical flagellar propulsion, at relatively low actuation frequencies.

pi

DOI [BibTex]

DOI [BibTex]


An XY ϴz flexure mechanism with optimal stiffness properties
An XY ϴz flexure mechanism with optimal stiffness properties

Lum, G. Z., Pham, M. T., Teo, T. J., Yang, G., Yeo, S. H., Sitti, M.

In 2017 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), pages: 1103-1110, July 2017 (inproceedings)

Abstract
The development of optimal XY θz flexure mechanisms, which can deliver high precision motion about the z-axis, and along the x- and y-axes is highly desirable for a wide range of micro/nano-positioning tasks pertaining to biomedical research, microscopy technologies and various industrial applications. Although maximizing the stiffness ratios is a very critical design requirement, the achievable translational and rotational stiffness ratios of existing XY θz flexure mechanisms are still restricted between 0.5 and 130. As a result, these XY θz flexure mechanisms are unable to fully optimize their workspace and capabilities to reject disturbances. Here, we present an optimal XY θz flexure mechanism, which is designed to have maximum stiffness ratios. Based on finite element analysis (FEA), it has translational stiffness ratio of 248, rotational stiffness ratio of 238 and a large workspace of 2.50 mm × 2.50 mm × 10°. Despite having such a large workspace, FEA also predicts that the proposed mechanism can still achieve a high bandwidth of 70 Hz. In comparison, the bandwidth of similar existing flexure mechanisms that can deflect more than 0.5 mm or 0.5° is typically less than 45 Hz. Hence, the high stiffness ratios of the proposed mechanism are achieved without compromising its dynamic performance. Preliminary experimental results pertaining to the mechanism's translational actuating stiffness and bandwidth were in agreement with the FEA predictions as the deviation was within 10%. In conclusion, the proposed flexure mechanism exhibits superior performance and can be used across a wide range of applications.

pi

DOI [BibTex]

DOI [BibTex]


Positioning of drug carriers using permanent magnet-based robotic system in three-dimensional space
Positioning of drug carriers using permanent magnet-based robotic system in three-dimensional space

Khalil, I. S. M., Alfar, A., Tabak, A. F., Klingner, A., Stramigioli, S., Sitti, M.

In 2017 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), pages: 1117-1122, July 2017 (inproceedings)

Abstract
Magnetic control of drug carriers using systems with open-configurations is essential to enable scaling to the size of in vivo applications. In this study, we demonstrate motion control of paramagnetic microparticles in a low Reynolds number fluid, using a permanent magnet-based robotic system with an open-configuration. The microparticles are controlled in three-dimensional (3D) space using a cylindrical NdFeB magnet that is fixed to the end-effector of a robotic arm. We develop a kinematic map between the position of the microparticles and the configuration of the robotic arm, and use this map as a basis of a closed-loop control system based on the position of the microparticles. Our experimental results show the ability of the robot configuration to control the exerted field gradient on the dipole of the microparticles, and achieve positioning in 3D space with maximum error of 300 µm and 600 µm in the steady-state during setpoint and trajectory tracking, respectively.

pi

DOI [BibTex]

DOI [BibTex]


no image
Self-assembly of micro/nanosystems across scales and interfaces

Mastrangeli, M.

In 2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), pages: 676 - 681, IEEE, July 2017 (inproceedings)

Abstract
Steady progress in understanding and implementation are establishing self-assembly as a versatile, parallel and scalable approach to the fabrication of transducers. In this contribution, I illustrate the principles and reach of self-assembly with three applications at different scales - namely, the capillary self-alignment of millimetric components, the sealing of liquid-filled polymeric microcapsules, and the accurate capillary assembly of single nanoparticles - and propose foreseeable directions for further developments.

pi

link (url) DOI [BibTex]

link (url) DOI [BibTex]


Locomotion of light-driven soft microrobots through a hydrogel via local melting
Locomotion of light-driven soft microrobots through a hydrogel via local melting

Palagi, S., Mark, A. G., Melde, K., Qiu, T., Zeng, H., Parmeggiani, C., Martella, D., Wiersma, D. S., Fischer, P.

In 2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS), pages: 1-5, July 2017 (inproceedings)

Abstract
Soft mobile microrobots whose deformation can be directly controlled by an external field can adapt to move in different environments. This is the case for the light-driven microrobots based on liquid-crystal elastomers (LCEs). Here we show that the soft microrobots can move through an agarose hydrogel by means of light-controlled travelling-wave motions. This is achieved by exploiting the inherent rise of the LCE temperature above the melting temperature of the agarose gel, which facilitates penetration of the microrobot through the hydrogel. The locomotion performance is investigated as a function of the travelling-wave parameters, showing that effective propulsion can be obtained by adapting the generated motion to the specific environmental conditions.

pf

DOI [BibTex]

DOI [BibTex]


Dynamic analysis on hexapedal water-running robot with compliant joints
Dynamic analysis on hexapedal water-running robot with compliant joints

Kim, H., Liu, Y., Jeong, K., Sitti, M., Seo, T.

In 2017 14th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI), pages: 250-251, June 2017 (inproceedings)

Abstract
The dynamic analysis has been considered as one of the important design methods to design robots. In this research, we derive dynamic equation of hexapedal water-running robot to design compliant joints. The compliant joints that connect three bodies will be used to improve mobility and stability of water-running motion's pitch behavior. We considered all of parts as rigid body including links of six Klann mechanisms and three main frames. And then, we derived dynamic equation by using the Lagrangian method with external force of the water. We are expecting that the dynamic analysis is going to be used to design parts of the water running robot.

pi

DOI [BibTex]

DOI [BibTex]


Design and actuation of a magnetic millirobot under a constant unidirectional magnetic field
Design and actuation of a magnetic millirobot under a constant unidirectional magnetic field

Erin, O., Giltinan, J., Tsai, L., Sitti, M.

In Proceedings 2017 IEEE International Conference on Robotics and Automation (ICRA), pages: 3404-3410, IEEE, Piscataway, NJ, USA, IEEE International Conference on Robotics and Automation (ICRA), May 2017 (inproceedings)

Abstract
Magnetic untethered millirobots, which are actuated and controlled by remote magnetic fields, have been proposed for medical applications due to their ability to safely pass through tissues at long ranges. For example, magnetic resonance imaging (MRI) systems with a 3-7 T constant unidirectional magnetic field and 3D gradient coils have been used to actuate magnetic robots. Such magnetically constrained systems place limits on the degrees of freedom that can be actuated for untethered devices. This paper presents a design and actuation methodology for a magnetic millirobot that exhibits both position and orientation control in 2D under a magnetic field, dominated by a constant unidirectional magnetic field as found in MRI systems. Placing a spherical permanent magnet, which is free to rotate inside the millirobot and located away from the center of mass, allows the generation of net forces and torques with applied 3D magnetic field gradients. We model this system in a 3D planar case and experimentally demonstrate open-loop control of both position and orientation by the applied 2D field gradients. The actuation performance is characterized across the most important design variables, and we experimentally demonstrate that the proposed approach is feasible.

pi

DOI [BibTex]

DOI [BibTex]


Magnetically actuated soft capsule endoscope for fine-needle aspiration biopsy
Magnetically actuated soft capsule endoscope for fine-needle aspiration biopsy

Son, D., Dogan, M. D., Sitti, M.

In Proceedings 2017 IEEE International Conference on Robotics and Automation (ICRA), pages: 1132-1139, IEEE, Piscataway, NJ, USA, IEEE International Conference on Robotics and Automation (ICRA), May 2017 (inproceedings)

Abstract
This paper presents a magnetically actuated soft capsule endoscope for fine-needle aspiration biopsy (B-MASCE) in the upper gastrointestinal tract. A thin and hollow needle is attached to the capsule, which can penetrate deeply into tissues to obtain subsurface biopsy sample. The design utilizes a soft elastomer body as a compliant mechanism to guide the needle. An internal permanent magnet provides a means for both actuation and tracking. The capsule is designed to roll towards its target and then deploy the biopsy needle in a precise location selected as the target area. B-MASCE is controlled by multiple custom-designed electromagnets while its position and orientation are tracked by a magnetic sensor array. In in vitro trials, B-MASCE demonstrated rolling locomotion and biopsy of a swine tissue model positioned inside an anatomical human stomach model. It was confirmed after the experiment that a tissue sample was retained inside the needle.

pi

DOI Project Page [BibTex]

DOI Project Page [BibTex]


Wireless micro-robots for endoscopic applications in urology
Wireless micro-robots for endoscopic applications in urology

Adams, F., Qiu, T., Mark, A. G., Melde, K., Palagi, S., Miernik, A., Fischer, P.

In Eur Urol Suppl, 16(3):e1914, March 2017 (inproceedings)

Abstract
Endoscopy is an essential and common method for both diagnostics and therapy in Urology. Current flexible endoscope is normally cable-driven, thus it is hard to be miniaturized and its reachability is restricted as only one bending section near the tip with one degree of freedom (DoF) is allowed. Recent progresses in micro-robotics offer a unique opportunity for medical inspections in minimally invasive surgery. Micro-robots are active devices that has a feature size smaller than one millimeter and can normally be actuated and controlled wirelessly. Magnetically actuated micro-robots have been demonstrated to propel through biological fluids.Here, we report a novel micro robotic arm, which is actuated wirelessly by ultrasound. It works as a miniaturized endoscope with a side length of ~1 mm, which fits through the 3 Fr. tool channel of a cystoscope, and successfully performs an active cystoscopy in a rabbit bladder.

pf

link (url) DOI [BibTex]


The use of clamping grips and friction pads by tree frogs for climbing curved surfaces
The use of clamping grips and friction pads by tree frogs for climbing curved surfaces

Endlein, T., Ji, A., Yuan, S., Hill, I., Wang, H., Barnes, W. J. P., Dai, Z., Sitti, M.

In Proc. R. Soc. B, 284(1849):20162867, Febuary 2017 (inproceedings)

Abstract
Most studies on the adhesive mechanisms of climbing animals have addressed attachment against flat surfaces, yet many animals can climb highly curved surfaces, like twigs and small branches. Here we investigated whether tree frogs use a clamping grip by recording the ground reaction forces on a cylindrical object with either a smooth or anti-adhesive, rough surface. Furthermore, we measured the contact area of fore and hindlimbs against differently sized transparent cylinders and the forces of individual pads and subarticular tubercles in restrained animals. Our study revealed that frogs use friction and normal forces of roughly a similar magnitude for holding on to cylindrical objects. When challenged with climbing a non-adhesive surface, the compressive forces between opposite legs nearly doubled, indicating a stronger clamping grip. In contrast to climbing flat surfaces, frogs increased the contact area on all limbs by engaging not just adhesive pads but also subarticular tubercles on curved surfaces. Our force measurements showed that tubercles can withstand larger shear stresses than pads. SEM images of tubercles revealed a similar structure to that of toe pads including the presence of nanopillars, though channels surrounding epithelial cells were less pronounced. The tubercles' smaller size, proximal location on the toes and shallow cells make them probably less prone to buckling and thus ideal for gripping curved surfaces.

pi

DOI [BibTex]

DOI [BibTex]


Planning spin-walking locomotion for automatic grasping of microobjects by an untethered magnetic microgripper
Planning spin-walking locomotion for automatic grasping of microobjects by an untethered magnetic microgripper

Dong, X., Sitti, M.

In 2017 IEEE International Conference on Robotics and Automation (ICRA), pages: 6612-6618, 2017 (inproceedings)

Abstract
Most demonstrated mobile microrobot tasks so far have been achieved via pick-and-placing and dynamic trapping with teleoperation or simple path following algorithms. In our previous work, an untethered magnetic microgripper has been developed which has advanced functions, such as gripping objects. Both teleoperated manipulation in 2D and 3D have been demonstrated. However, it is challenging to control the magnetic microgripper to carry out manipulation tasks, because the grasping of objects so far in the literature relies heavily on teleoperation, which takes several minutes with even a skilled human expert. Here, we propose a new spin-walking locomotion and an automated 2D grasping motion planner for the microgripper, which enables time-efficient automatic grasping of microobjects that has not been achieved yet for untethered microrobots. In its locomotion, the microgripper repeatedly rotates about two principal axes to regulate its pose and move precisely on a surface. The motion planner could plan different motion primitives for grasping and compensate the uncertainties in the motion by learning the uncertainties and planning accordingly. We experimentally demonstrated that, using the proposed method, the microgripper could align to the target pose with error less than 0.1 body length and grip the objects within 40 seconds. Our method could significantly improve the time efficiency of micro-scale manipulation and have potential applications in microassembly and biomedical engineering.

pi

DOI Project Page [BibTex]

DOI Project Page [BibTex]

2004


no image
E. coli inspired propulsion for swimming microrobots

Behkam, B., Sitti, M.

In ASME 2004 International Mechanical Engineering Congress and Exposition, pages: 1037-1041, 2004 (inproceedings)

pi

Project Page [BibTex]

2004


Project Page [BibTex]


no image
Dynamic modes of nanoparticle motion during nanoprobe-based manipulation

Tafazzoli, A., Sitti, M.

In Nanotechnology, 2004. 4th IEEE Conference on, pages: 35-37, 2004 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Modeling and design of biomimetic adhesives inspired by gecko foot-hairs

Shah, G. J., Sitti, M.

In Robotics and Biomimetics, 2004. ROBIO 2004. IEEE International Conference on, pages: 873-878, 2004 (inproceedings)

pi

Project Page [BibTex]

Project Page [BibTex]


no image
High-speed dynamics of magnetization processes in hard magnetic particles and thin platelets

Goll, D., Kronmüller, H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 465-469, Laboratoire de Cristallographie/Laboratoire Louis Neel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Nanoscale Materials for Energy Storage
{Materials Science \& Engineering B}, 108, pages: 292, Elsevier, 2004 (misc)

mms

[BibTex]

[BibTex]


no image
Augmented reality user interface for nanomanipulation using atomic force microscopes

Vogl, W., Sitti, M., Ehrenstrasser, M., Zäh, M.

In Proc. of Eurohaptics, pages: 413-416, 2004 (inproceedings)

pi

[BibTex]

[BibTex]


no image
WaalBots for Space applications

Menon, C., Murphy, M., Angrilli, F., Sitti, M.

In 55th IAC Conference, Vancouver, Canada, 2004 (inproceedings)

pi

[BibTex]

[BibTex]


no image
High-speed dynamics of magnetization processes in hard magnetic particles and thin platelets

Goll, D., Kronmüller, H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 465-469, Laboratoire de Cristallographie/Laboratoire Louis Neel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Modern nanocrystalline/nanostructured hard magnetic materials

Kronmüller, H., Goll, D.

In 272-276, pages: e319-e320, Rome [Italy], 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Modern nanostructured high-temperature permanent magnets

Goll, D., Kronmüller, H., Stadelmaier, H. H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 578-583, Laboratoire de Cristallographie/Laboratoire Louis Néel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Dynamic behavior and simulation of nanoparticle sliding during nanoprobe-based positioning

Tafazzoli, A., Sitti, M.

In Proc. ASME International Mechanical Engineering Conference, 19, pages: 32, 2004 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Imaging sub-ns spin dynamics in magnetic nanostructures with magnetic transmission X-ray microscopy

Fischer, P., Stoll, H., Puzic, A., Van Waeyenberge, B., Raabe, J., Haug, T., Denbeaux, G., Pearson, A., Höllinger, R., Back, C. H., Weiss, D., Schütz, G.

In Synchrotron Radiation Instrumentation, 705, pages: 1291-1294, AIP Conference Proceedings, American Institute of Physics, San Francisco, California (USA), 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Modern nanostructured high-temperature permanent magnets

Goll, D., Kronmüller, H., Stadelmaier, H. H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 578-583, Laboratoire de Cristallographie/Laboratoire Louis Néel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Existence of transient temperature spike induced by SHI: evidence by ion beam analysis

Avasthi, D. K., Ghosh, S., Srivastava, S. K., Assmann, W.

In 219-220, pages: 206-214, Albuquerque, NM [USA], 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Three-dimensional nanoscale manipulation and manufacturing using proximal probes: controlled pulling of polymer micro/nanofibers

Nain, A. S., Amon, C., Sitti, M.

In Mechatronics, 2004. ICM’04. Proceedings of the IEEE International Conference on, pages: 224-230, 2004 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Micro-and nano-scale robotics

Sitti, M.

In American Control Conference, 2004. Proceedings of the 2004, 1, pages: 1-8, 2004 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Gecko inspired surface climbing robots

Menon, C., Murphy, M., Sitti, M.

In Robotics and Biomimetics, 2004. ROBIO 2004. IEEE International Conference on, pages: 431-436, 2004 (inproceedings)

pi

Project Page [BibTex]

Project Page [BibTex]


no image
Hard magnetic hollow nanospheres

Goll, D., Berkowitz, A. E., Bertram, H. N.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 704-707, Laboratoire de Cristallographie/Laboratoire Louis Neel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]

2000


no image
High-performance nanocrystalline PrFeB-based bonded permanent magnets

Goll, D., Kleinschroth, I., Kronmüller, H.

In Proceedings of the 16th International Workshop on Rare-Earth Magnets and Their Applications, pages: 641-650, Japan Institute of Metals, 2000 (inproceedings)

mms

[BibTex]

2000


[BibTex]


no image
Experimental and theoretical study of the Verwey transition in magnetite

Brabers, V. A. M., Brabers, J. H. V. J., Walz, F., Kronmüller, H.

In Proceedings 8th International Conference on Ferrites, pages: 123-125, Japan Society of Powder and Powder Metallurgy, 2000 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Evolution of microstructure and microchemistry in the high-temperature Sm(Co, Fe, Cu, Zr)z magnets

Zhang, Y. W., Hadjipanayis, G. C., Goll, D., Kronmüller, H., Chen, C., Nelson, C., Krishnan, K.

In Proceedings of the 16th International Workshop on Rare-Earth Magnets and Their Applications, pages: 169-178, Sendai, Japan, 2000 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Fundamental investigations and industrial applications of magnetostriction

Hirscher, M., Fischer, S. F., Reininger, T.

In Modern Trends in Magnetostriction Study and Application. Proceedings of the NATO Advanced Study Institute on Modern Trends in Magnetostriction, 5, pages: 307-329, NATO Science Series: II: Mathematics, Physics and Chemistry, Kluwer Academic Publishers, Kyiv, Ukraine, 2000 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Micromagnetic and microstructural analysis of the temperature dependence of the coercive field of Sm2(Co, Cu, Fe, Zr)17 permanent magnets

Goll, D., Sigle, W., Hadjipanayis, G. C., Kronmüller, H.

In Proceedings of the 16th International Workshop on Rare-Earth Magnets and Their Applications, pages: 61-70, Kaneko, H.; Homma, M.; Okada, M., 2000 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Wing transmission for a micromechanical flying insect

Fearing, R. S., Chiang, K. H., Dickinson, M. H., Pick, D., Sitti, M., Yan, J.

In Robotics and Automation, 2000. Proceedings. ICRA’00. IEEE International Conference on, 2, pages: 1509-1516, 2000 (inproceedings)

pi

[BibTex]

[BibTex]