Header logo is


2012


Thumb xl coregtr
Coregistration: Supplemental Material

Hirshberg, D., Loper, M., Rachlin, E., Black, M. J.

(No. 4), Max Planck Institute for Intelligent Systems, October 2012 (techreport)

ps

pdf [BibTex]

2012


pdf [BibTex]


Thumb xl lietr
Lie Bodies: A Manifold Representation of 3D Human Shape. Supplemental Material

Freifeld, O., Black, M. J.

(No. 5), Max Planck Institute for Intelligent Systems, October 2012 (techreport)

ps

pdf Project Page [BibTex]

pdf Project Page [BibTex]


Thumb xl sinteltr
MPI-Sintel Optical Flow Benchmark: Supplemental Material

Butler, D. J., Wulff, J., Stanley, G. B., Black, M. J.

(No. 6), Max Planck Institute for Intelligent Systems, October 2012 (techreport)

ps

pdf Project Page [BibTex]

pdf Project Page [BibTex]


no image
Blind Retrospective Motion Correction of MR Images

Loktyushin, A., Nickisch, H., Pohmann, R., Schölkopf, B.

20th Annual Scientific Meeting ISMRM, May 2012 (poster)

Abstract
Patient motion in the scanner is one of the most challenging problems in MRI. We propose a new retrospective motion correction method for which no tracking devices or specialized sequences are required. We seek the motion parameters such that the image gradients in the spatial domain become sparse. We then use these parameters to invert the motion and recover the sharp image. In our experiments we acquired 2D TSE images and 3D FLASH/MPRAGE volumes of the human head. Major quality improvements are possible in the 2D case and substantial improvements in the 3D case.

ei

Web [BibTex]

Web [BibTex]


no image
High Gamma-Power Predicts Performance in Brain-Computer Interfacing

Grosse-Wentrup, M., Schölkopf, B.

(3), Max-Planck-Institut für Intelligente Systeme, Tübingen, February 2012 (techreport)

Abstract
Subjects operating a brain-computer interface (BCI) based on sensorimotor rhythms exhibit large variations in performance over the course of an experimental session. Here, we show that high-frequency gamma-oscillations, originating in fronto-parietal networks, predict such variations on a trial-to-trial basis. We interpret this nding as empirical support for an in uence of attentional networks on BCI-performance via modulation of the sensorimotor rhythm.

ei

PDF [BibTex]

PDF [BibTex]


Thumb xl humim2012
HUMIM Software for Articulated Tracking

Soren Hauberg, Kim S. Pedersen

(01/2012), Department of Computer Science, University of Copenhagen, January 2012 (techreport)

ps

Code PDF [BibTex]

Code PDF [BibTex]


Thumb xl tr feragen2012
A geometric framework for statistics on trees

Aasa Feragen, Mads Nielsen, Soren Hauberg, Pechin Lo, Marleen de Bruijne, Francois Lauze

(11/02), Department of Computer Science, University of Copenhagen, January 2012 (techreport)

ps

PDF [BibTex]

PDF [BibTex]


no image
Identifying endogenous rhythmic spatio-temporal patterns in micro-electrode array recordings

Besserve, M., Panagiotaropoulos, T., Crocker, B., Kapoor, V., Tolias, A., Panzeri, S., Logothetis, N.

9th annual Computational and Systems Neuroscience meeting (Cosyne), 2012 (poster)

ei

[BibTex]

[BibTex]


no image
Reconstruction using Gaussian mixture models

Joubert, P., Habeck, M.

2012 Gordon Research Conference on Three-Dimensional Electron Microscopy (3DEM), 2012 (poster)

ei

Web [BibTex]

Web [BibTex]


no image
Learning from Distributions via Support Measure Machines

Muandet, K., Fukumizu, K., Dinuzzo, F., Schölkopf, B.

26th Annual Conference on Neural Information Processing Systems (NIPS), 2012 (poster)

ei

PDF [BibTex]

PDF [BibTex]


no image
Juggling Increases Interhemispheric Brain Connectivity: A Visual and Quantitative dMRI Study.

Schultz, T., Gerber, P., Schmidt-Wilcke, T.

Vision, Modeling and Visualization (VMV), 2012 (poster)

ei

[BibTex]

[BibTex]


no image
The geometry and statistics of geometric trees

Feragen, A., Lo, P., de Bruijne, M., Nielsen, M., Lauze, F.

T{\"u}bIt day of bioinformatics, June, 2012 (poster)

ei

[BibTex]

[BibTex]


no image
Therapy monitoring of patients with chronic sclerodermic graft-versus-host-disease using PET/MRI

Sauter, A., Schmidt, H., Mantlik, F., Kolb, A., Federmann, B., Bethge, W., Reimold, M., Pfannenberg, C., Pichler, B., Horger, M.

2012 SNM Annual Meeting, 2012 (poster)

ei

Web [BibTex]

Web [BibTex]


no image
Centrality of the Mammalian Functional Brain Network

Besserve, M., Bartels, A., Murayama, Y., Logothetis, N.

42nd Annual Meeting of the Society for Neuroscience (Neuroscience), 2012 (poster)

ei

[BibTex]

[BibTex]


no image
Kernel Mean Embeddings of POMDPs

Nishiyama, Y., Boularias, A., Gretton, A., Fukumizu, K.

21st Machine Learning Summer School , 2012 (poster)

ei

[BibTex]

[BibTex]


no image
Semi-Supervised Domain Adaptation with Copulas

Lopez-Paz, D., Hernandez-Lobato, J., Schölkopf, B.

Neural Information Processing Systems (NIPS), 2012 (poster)

ei

PDF [BibTex]

PDF [BibTex]


no image
Evaluation of Whole-Body MR-Based Attenuation Correction in Bone and Soft Tissue Lesions

Bezrukov, I., Mantlik, F., Schmidt, H., Schwenzer, N., Brendle, C., Schölkopf, B., Pichler, B.

Nuclear Science Symposium and Medical Imaging Conference (NSS-MIC), 2012 (poster)

ei

[BibTex]

[BibTex]


no image
The PET Performance Measurements of A Next Generation Dedicated Small Animal PET/MR Scanner

Liu, C., Hossain, M., Bezrukov, I., Wehrl, H., Kolb, A., Judenhofer, M., Pichler, B.

World Molecular Imaging Congress (WMIC), 2012 (poster)

ei

[BibTex]

[BibTex]

1998


no image
Masking by plaid patterns: effects of presentation time and mask contrast

Wichmann, F., Henning, G.

pages: 115, 1. T{\"u}binger Wahrnehmungskonferenz (TWK 98), February 1998 (poster)

Abstract
Most current models of early spatial vision comprise of sets of orientation- and spatial-frequency selective filters with our without limited non-linear interactions amongst different subsets of the filters. The performance of human observers and of such models for human spatial vision were compared in experiments using maskers with two spatial frequencies (plaid masks). The detectability of horizontally orientated sinusoidal signals at 3.02 c/deg was measured in standard 2AFC-tasks in the presence of plaid patterns with two-components at the same spatial frequency as the signal but at different orientations (+/- 15, 30, 45, and 75 deg from the signal) and with varying contrasts (1.0, 6.25 and 25.0% contrast). In addition, the temporal envelope of the stimulus presentation was either a rectangular pulse of 19.7 msec duration, or a temporal Hanning window of 1497 msec.Threshold elevation varied with plaid component orientation, peaked +/- 30 deg from the signal where nearly a log unit threshold elevation for the 25.0% contrast plaid was observed. For plaids with 1.0% contrast we observed significant facilitation even with plaids whose components were 75 deg from that of the signal. Elevation factors were somewhat lower for the short stimulus presentation time but were still significant (up to a factor of 5 or 6). Despite of the simple nature of the stimuli employed in this study-sinusoidal signal and plaid masks comprised of only two sinusoids-none of the current models of early spatial vision can fully account for all the data gathered.

ei

Web [BibTex]

1998


Web [BibTex]


no image
Generalization bounds and learning rates for Regularized principal manifolds

Smola, A., Williamson, R., Schölkopf, B.

NeuroCOLT, 1998, NeuroColt2-TR 1998-027 (techreport)

ei

[BibTex]

[BibTex]


no image
Generalization Bounds for Convex Combinations of Kernel Functions

Smola, A., Williamson, R., Schölkopf, B.

Royal Holloway College, 1998 (techreport)

ei

[BibTex]

[BibTex]


no image
Generalization Performance of Regularization Networks and Support Vector Machines via Entropy Numbers of Compact Operators

Williamson, R., Smola, A., Schölkopf, B.

(19), NeuroCOLT, 1998, Accepted for publication in IEEE Transactions on Information Theory (techreport)

ei

[BibTex]

[BibTex]


no image
A bootstrap method for testing hypotheses concerning psychometric functions

Hill, N., Wichmann, F.

1998 (poster)

Abstract
Whenever psychometric functions are used to evaluate human performance on some task, it is valuable to examine not only the threshold and slope values estimated from the original data, but also the expected variability in those measures. This allows psychometric functions obtained in two experimental conditions to be compared statistically. We present a method for estimating the variability of thresholds and slopes of psychometric functions. This involves a maximum-likelihood fit to the data using a three-parameter mathematical function, followed by Monte Carlo simulation using the first fit as a generating function for the simulations. The variability of the function's parameters can then be estimated (as shown by Maloney, 1990), as can the variability of the threshold value (Foster & Bischof, 1997). We will show how a simple development of this procedure can be used to test the significance of differences between (a) the thresholds, and (b) the slopes of two psychometric functions. Further, our method can be used to assess the assumptions underlying the original fit, by examining how goodness-of-fit differs in simulation from its original value. In this way data sets can be identified as being either too noisy to be generated by a binomial observer, or significantly "too good to be true." All software is written in MATLAB and is therefore compatible across platforms, with the option of accelerating performance using MATLAB's plug-in binaries, or "MEX" files.

ei

[BibTex]


no image
Quantization Functionals and Regularized PrincipalManifolds

Smola, A., Mika, S., Schölkopf, B.

NeuroCOLT, 1998, NC2-TR-1998-028 (techreport)

ei

[BibTex]

[BibTex]


no image
Nonlinearities and the pedestal effect

Wichmann, F., Henning, G., Ploghaus, A.

Perception, 27, pages: S86, 1998 (poster)

Abstract
Psychophysical and physiological evidence suggests that luminance patterns are independently analysed in "channels" responding to different bands of spatial frequency. There are, however, interactions among stimuli falling well outside the usual estimates of channels' bandwidths (Henning, Hertz, and Broadbent, (1975). Vision Res., 15, 887-899). We examined whether the masking results of Henning et al. are consistent with independent channels. We postulated, before the channels, a point non-linearity which would introduce distortion products that might produce the observed interactions between stimuli two octaves apart in spatial frequency. Standard 2-AFC masking experiments determined whether possible distortion products of a 4.185 c/deg masking sinusoid revealed their presence through effects on the detection of a sinusoidal signal at the frequency of the second harmonic of the masker-8.37 c/deg. The signal and masker were horizontally orientated and the signal was in-phase, out-of-phase, or in quadrature with the putative second-order distortion product of the masker. Significant interactions between signal and masker were observed: for a wide range of masker contrasts, signal detection was facilitated by the masking stimulus. However, the shapes of the functions relating detection performance to masker contrast, as well as the effects of relative phase, were inconsistent with the notion that distortion products were responsible for the interactions observed.

ei

[BibTex]

[BibTex]


no image
Support Vector Machine Reference Manual

Saunders, C., Stitson, M., Weston, J., Bottou, L., Schölkopf, B., Smola, A.

(CSD-TR-98-03), Department of Computer Science, Royal Holloway, University of London, 1998 (techreport)

ei

PostScript [BibTex]

PostScript [BibTex]