Header logo is


2016


Thumb xl toc image
Wireless actuation with functional acoustic surfaces

Qiu, T., Palagi, S., Mark, A. G., Melde, K., Adams, F., Fischer, P.

Appl. Phys. Lett., 109(19):191602, November 2016, APL Editor's pick. APL News. (article)

Abstract
Miniaturization calls for micro-actuators that can be powered wirelessly and addressed individually. Here, we develop functional surfaces consisting of arrays of acoustically resonant microcavities, and we demonstrate their application as two-dimensional wireless actuators. When remotely powered by an acoustic field, the surfaces provide highly directional propulsive forces in fluids through acoustic streaming. A maximal force of similar to 0.45mN is measured on a 4 x 4 mm(2) functional surface. The response of the surfaces with bubbles of different sizes is characterized experimentally. This shows a marked peak around the micro-bubbles' resonance frequency, as estimated by both an analytical model and numerical simulations. The strong frequency dependence can be exploited to address different surfaces with different acoustic frequencies, thus achieving wireless actuation with multiple degrees of freedom. The use of the functional surfaces as wireless ready-to-attach actuators is demonstrated by implementing a wireless and bidirectional miniaturized rotary motor, which is 2.6 x 2.6 x 5 mm(3) in size and generates a stall torque of similar to 0.5 mN.mm. The adoption of micro-structured surfaces as wireless actuators opens new possibilities in the development of miniaturized devices and tools for fluidic environments that are accessible by low intensity ultrasound fields.

pf

link (url) DOI Project Page [BibTex]

2016


link (url) DOI Project Page [BibTex]


Thumb xl 1 00000
Bioengineered and biohybrid bacteria-based systems for drug delivery

Hosseinidoust, Z., Mostaghaci, B., Yasa, O., Park, B., Singh, A. V., Sitti, M.

Advanced Drug Delivery Reviews, 106, pages: 27-44, Elsevier, November 2016 (article)

Abstract
The use of bacterial cells as agents of medical therapy has a long history. Research that was ignited over a century ago with the accidental infection of cancer patients has matured into a platform technology that offers the promise of opening up new potential frontiers in medical treatment. Bacterial cells exhibit unique characteristics that make them well-suited as smart drug delivery agents. Our ability to genetically manipulate the molecular machinery of these cells enables the customization of their therapeutic action as well as its precise tuning and spatio-temporal control, allowing for the design of unique, complex therapeutic functions, unmatched by current drug delivery systems. Early results have been promising, but there are still many important challenges that must be addressed. We present a review of promises and challenges of employing bioengineered bacteria in drug delivery systems and introduce the biohybrid design concept as a new additional paradigm in bacteria-based drug delivery.

pi

DOI Project Page [BibTex]

DOI Project Page [BibTex]


Thumb xl toc image
Nanomotors

Alarcon-Correa, M., Walker (Schamel), D., Qiu, T., Fischer, P.

Eur. Phys. J.-Special Topics, 225(11-12):2241-2254, November 2016 (article)

Abstract
This minireview discusses whether catalytically active macromolecules and abiotic nanocolloids, that are smaller than motile bacteria, can self-propel. Kinematic reversibility at low Reynolds number demands that self-propelling colloids must break symmetry. Methods that permit the synthesis and fabrication of Janus nanocolloids are therefore briefly surveyed, as well as means that permit the analysis of the nanocolloids' motion. Finally, recent work is reviewed which shows that nanoagents are small enough to penetrate the complex inhomogeneous polymeric network of biological fluids and gels, which exhibit diverse rheological behaviors.

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image
Structured light enables biomimetic swimming and versatile locomotion of photoresponsive soft microrobots

Palagi, S., Mark, A. G., Reigh, S. Y., Melde, K., Qiu, T., Zeng, H., Parmeggiani, C., Martella, D., Sanchez-Castillo, A., Kapernaum, N., Giesselmann, F., Wiersma, D. S., Lauga, E., Fischer, P.

Nature Materials, 15(6):647–653, November 2016, Max Planck press release, Nature News & Views. (article)

Abstract
Microorganisms move in challenging environments by periodic changes in body shape. In contrast, current artificial microrobots cannot actively deform, exhibiting at best passive bending under external fields. Here, by taking advantage of the wireless, scalable and spatiotemporally selective capabilities that light allows, we show that soft microrobots consisting of photoactive liquid-crystal elastomers can be driven by structured monochromatic light to perform sophisticated biomimetic motions. We realize continuum yet selectively addressable artificial microswimmers that generate travelling-wave motions to self-propel without external forces or torques, as well as microrobots capable of versatile locomotion behaviours on demand. Both theoretical predictions and experimental results confirm that multiple gaits, mimicking either symplectic or antiplectic metachrony of ciliate protozoa, can be achieved with single microswimmers. The principle of using structured light can be extended to other applications that require microscale actuation with sophisticated spatiotemporal coordination for advanced microrobotic technologies.

pf

Video - Soft photo Micro-Swimmer DOI [BibTex]

Video - Soft photo Micro-Swimmer DOI [BibTex]


Thumb xl 07759726
Steering control of a water-running robot using an active tail

Kim, H., Jeong, K., Sitti, M., Seo, T.

In Intelligent Robots and Systems (IROS), 2016 IEEE/RSJ International Conference on, pages: 4945-4950, October 2016 (inproceedings)

Abstract
Many highly dynamic novel mobile robots have been developed being inspired by animals. In this study, we are inspired by a basilisk lizard's ability to run and steer on water surface for a hexapedal robot. The robot has an active tail with a circular plate, which the robot rotates to steer on water. We dynamically modeled the platform and conducted simulations and experiments on steering locomotion with a bang-bang controller. The robot can steer on water by rotating the tail, and the controlled steering locomotion is stable. The dynamic modelling approximates the robot's steering locomotion and the trends of the simulations and experiments are similar, although there are errors between the desired and actual angles. The robot's maneuverability on water can be improved through further research.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl 07293677
A 5-D localization method for a magnetically manipulated untethered robot using a 2-D array of Hall-effect sensors

Son, D., Yim, S., Sitti, M.

IEEE/ASME Transactions on Mechatronics, 21(2):708-716, IEEE, October 2016 (article)

Abstract
This paper introduces a new five-dimensional localization method for an untethered meso-scale magnetic robot, which is manipulated by a computer-controlled electromagnetic system. The developed magnetic localization setup is a two-dimensional array of mono-axial Hall-effect sensors, which measure the perpendicular magnetic fields at their given positions. We introduce two steps for localizing a magnetic robot more accurately. First, the dipole modeled magnetic field of the electromagnet is subtracted from the measured data in order to determine the robot's magnetic field. Secondly, the subtracted magnetic field is twice differentiated in the perpendicular direction of the array, so that the effect of the electromagnetic field in the localization process is minimized. Five variables regarding the position and orientation of the robot are determined by minimizing the error between the measured magnetic field and the modeled magnetic field in an optimization method. The resulting position error is 2.1±0.8 mm and angular error is 6.7±4.3° within the applicable range (5 cm) of magnetic field sensors at 200 Hz. The proposed localization method would be used for the position feedback control of untethered magnetic devices or robots for medical applications in the future.

pi

DOI Project Page [BibTex]

DOI Project Page [BibTex]


Thumb xl nn 2016 05545f 0007
High-Performance Multiresponsive Paper Actuators

Amjadi, M., Sitti, M.

ACS Nano, 10(11):10202-10210, American Chemical Society, October 2016 (article)

Abstract
There is an increasing demand for soft actuators because of their importance in soft robotics, artificial muscles, biomimetic devices, and beyond. However, the development of soft actuators capable of low-voltage operation, powerful actuation, and programmable shape-changing is still challenging. In this work, we propose programmable bilayer actuators that operate based on the large hygroscopic contraction of the copy paper and simultaneously large thermal expansion of the polypropylene film upon increasing the temperature. The electrothermally activated bending actuators can function with low voltages (≤ 8 V), low input electric power per area (P ≤ 0.14 W cm–2), and low temperature changes (≤ 35 °C). They exhibit reversible shape-changing behavior with curvature radii up to 1.07 cm–1 and bending angle of 360°, accompanied by powerful actuation. Besides the electrical activation, they can be powered by humidity or light irradiation. We finally demonstrate the use of our paper actuators as a soft gripper robot and a lightweight paper wing for aerial robotics.

pi

DOI Project Page Project Page [BibTex]

DOI Project Page Project Page [BibTex]


Thumb xl publications toc
Programmable assembly of heterogeneous microparts by an untethered mobile capillary microgripper

Giltinan, J., Diller, E., Sitti, M.

Lab on a Chip, 16(22):4445-4457, Royal Society of Chemistry, October 2016 (article)

Abstract
At the sub-millimeter scale, capillary forces enable robust and reversible adhesion between biological organisms and varied substrates. Current human-engineered mobile untethered micromanipulation systems rely on forces which scale poorly or utilize gripper-part designs that promote manipulation. Capillary forces, alternatively, are dependent upon the surface chemistry (which is scale independent) and contact perimeter, which conforms to the part surface. We report a mobile capillary microgripper that is able to pick and place parts of various materials and geometries, and is thus ideal for microassembly tasks that cannot be accomplished by large tethered manipulators. We achieve the programmable assembly of sub-millimeter parts in an enclosed three-dimensional aqueous environment by creating a capillary bridge between the targeted part and a synthetic, untethered, mobile body. The parts include both hydrophilic and hydrophobic components: hydrogel, kapton, human hair, and biological tissue. The 200 μm untethered system can be controlled with five-degrees-of-freedom and advances progress towards autonomous desktop manufacturing for tissue engineering, complex micromachines, microfluidic devices, and meta-materials.

pi

DOI Project Page [BibTex]

DOI Project Page [BibTex]


Thumb xl 5fc6a94719a2ed61820a6fd031f53c39682a1f157b1c10c35d5d4c88d087d90e
Composition-dependent underwater adhesion of catechol-bearing hydrogels

Wu, H., Sariola, V., Zhao, J., Ding, H., Sitti, M., Bettinger, C. J.

Polymer International, 65(11):1355-1359, John Wiley & Sons, Ltd, September 2016 (article)

Abstract
Interfacial adhesion-mediated transfer printing processes can integrate functional electronic microstructures with polymeric substrates that are bendable and stretchable. Transfer printing has also been extended to catechol-bearing adhesive hydrogels. This study presents indentation adhesion tests between catechol-bearing hydrogel substrates with catechol concentrations varying from 0 to 10% (mol/mol) and thin-film materials commonly used in microelectronic fabrication including polymers, noble metals and oxides. The results indicate that the interfacial adhesion of catechol-bearing hydrogels is positively correlated with the concentration of catechol-bearing monomers as well as the retraction velocity during transfer printing. This study can inform transfer printing processes for microfabricated structures to compliant hydrated substrates such as hygroscopic monomers, mesoporous polymer networks and hydrogels. © 2016 Society of Chemical Industry

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl singh et al 2016 advanced healthcare materials
Bacteria-Driven Particles: Patterned and Specific Attachment of Bacteria on Biohybrid Bacteria-Driven Microswimmers (Adv. Healthcare Mater. 18/2016)

Singh, A. V., Sitti, M.

Advanced Healthcare Materials, 5(18):2306-2306, September 2016 (article)

Abstract
On page 2325, Ajay Vikram Singh and Metin Sitti propose a facile surface patterning technique and a specific, strong biotin–streptavidin bonding of bacteria on patterned surfaces to fabricate Janus particles that are propelled by the attached bacteria. Such bacteria-driven Janus microswimmers could be used for future medicine in targeted drug delivery and environmental remediation.

pi

DOI Project Page [BibTex]


Thumb xl toc image
Capture of 2D Microparticle Arrays via a UV-Triggered Thiol-yne “Click” Reaction

Walker (Schamel), D., Singh, D. P., Fischer, P.

Advanced Materials, 28(44):9846-9850, September 2016 (article)

Abstract
Immobilization of colloidal assemblies onto solid supports via a fast UV-triggered click-reaction is achieved. Transient assemblies of microparticles and colloidal materials can be captured and transferred to solid supports. The technique does not require complex reaction conditions, and is compatible with a variety of particle assembly methods.

pf

DOI [BibTex]


Thumb xl toc image
Magnesium plasmonics for UV applications and chiral sensing

Jeong, H. H., Mark, A. G., Fischer, P.

Chem. Comm., 52(82):12179-12182, September 2016 (article)

Abstract
We demonstrate that chiral magnesium nanoparticles show remarkable plasmonic extinction- and chiroptical-effects in the ultraviolet region. The Mg nanohelices possess an enhanced local surface plasmon resonance (LSPR) sensitivity due to the strong dispersion of most substances in the UV region.

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl cover nature 1j 00008
Holograms for acoustics

Melde, K., Mark, A. G., Qiu, T., Fischer, P.

Nature, 537, pages: 518-522, September 2016, Max Planck press release, Nature News & Views, Nature Video. (article)

Abstract
Holographic techniques are fundamental to applications such as volumetric displays(1), high-density data storage and optical tweezers that require spatial control of intricate optical(2) or acoustic fields(3,4) within a three-dimensional volume. The basis of holography is spatial storage of the phase and/or amplitude profile of the desired wavefront(5,6) in a manner that allows that wavefront to be reconstructed by interference when the hologram is illuminated with a suitable coherent source. Modern computer-generated holography(7) skips the process of recording a hologram from a physical scene, and instead calculates the required phase profile before rendering it for reconstruction. In ultrasound applications, the phase profile is typically generated by discrete and independently driven ultrasound sources(3,4,8-12); however, these can only be used in small numbers, which limits the complexity or degrees of freedom that can be attained in the wavefront. Here we introduce monolithic acoustic holograms, which can reconstruct diffraction-limited acoustic pressure fields and thus arbitrary ultrasound beams. We use rapid fabrication to craft the holograms and achieve reconstruction degrees of freedom two orders of magnitude higher than commercial phased array sources. The technique is inexpensive, appropriate for both transmission and reflection elements, and scales well to higher information content, larger aperture size and higher power. The complex three-dimensional pressure and phase distributions produced by these acoustic holograms allow us to demonstrate new approaches to controlled ultrasonic manipulation of solids in water, and of liquids and solids in air. We expect that acoustic holograms will enable new capabilities in beam-steering and the contactless transfer of power, improve medical imaging, and drive new applications of ultrasound.

pf

Video - Holograms for Sound DOI Project Page [BibTex]

Video - Holograms for Sound DOI Project Page [BibTex]


Thumb xl toc image
A loop-gap resonator for chirality-sensitive nuclear magneto-electric resonance (NMER)

Garbacz, P., Fischer, P., Kraemer, S.

J. Chem. Phys., 145(10):104201, September 2016 (article)

Abstract
Direct detection of molecular chirality is practically impossible by methods of standard nuclear magnetic resonance (NMR) that is based on interactions involving magnetic-dipole and magnetic-field operators. However, theoretical studies provide a possible direct probe of chirality by exploiting an enantiomer selective additional coupling involving magnetic-dipole, magnetic-field, and electric field operators. This offers a way for direct experimental detection of chirality by nuclear magneto-electric resonance (NMER). This method uses both resonant magnetic and electric radiofrequency (RF) fields. The weakness of the chiral interaction though requires a large electric RF field and a small transverse RF magnetic field over the sample volume, which is a non-trivial constraint. In this study, we present a detailed study of the NMER concept and a possible experimental realization based on a loop-gap resonator. For this original device, the basic principle and numerical studies as well as fabrication and measurements of the frequency dependence of the scattering parameter are reported. By simulating the NMER spin dynamics for our device and taking the F-19 NMER signal of enantiomer-pure 1,1,1-trifluoropropan-2-ol, we predict a chirality induced NMER signal that accounts for 1%-5% of the standard achiral NMR signal. Published by AIP Publishing.

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl publications toc
The effect of temperature and humidity on adhesion of a gecko-inspired adhesive: implications for the natural system

Stark, A. Y., Klittich, M. R., Sitti, M., Niewiarowski, P. H., Dhinojwala, A.

Scientific Reports, 6, pages: 30936, Nature Publishing Group, August 2016 (article)

Abstract
The adhesive system of geckos has inspired hundreds of synthetic adhesives. While this system has been used relentlessly as a source of inspiration, less work has been done in reverse, where synthetics are used to test questions and hypotheses about the natural system. Here we take such an approach. We tested shear adhesion of a mushroom-tipped synthetic gecko adhesive under conditions that produced perplexing results in the natural adhesive system. Synthetic samples were tested at two temperatures (12 °C and 32 °C) and four different humidity levels (30%, 55%, 70%, and 80% RH). Surprisingly, adhesive performance of the synthetic samples matched that of living geckos, suggesting that uncontrolled parameters in the natural system, such as surface chemistry and material changes, may not be as influential in whole-animal performance as previously thought. There was one difference, however, when comparing natural and synthetic adhesive performance. At 12 °C and 80% RH, adhesion of the synthetic structures was lower than expected based on the natural system’s performance. Our approach highlights a unique opportunity for both biologists and material scientists, where new questions and hypotheses can be fueled by joint comparisons of the natural and synthetic systems, ultimately improving knowledge of both.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl 07523675
Targeting of cell mockups using sperm-shaped microrobots in vitro

Khalil, I. S., Tabak, A. F., Hosney, A., Klingner, A., Shalaby, M., Abdel-Kader, R. M., Serry, M., Sitti, M.

In Biomedical Robotics and Biomechatronics (BioRob), 2016 6th IEEE International Conference on, pages: 495-501, July 2016 (inproceedings)

Abstract
Sperm-shaped microrobots are controlled under the influence of weak oscillating magnetic fields (milliTesla range) to selectively target cell mockups (i.e., gas bubbles with average diameter of 200 μm). The sperm-shaped microrobots are fabricated by electrospinning using a solution of polystyrene, dimethylformamide, and iron oxide nanoparticles. These nanoparticles are concentrated within the head of the microrobot, and hence enable directional control along external magnetic fields. The magnetic dipole moment of the microrobot is characterized (using the flip-time technique) to be 1.4×10-11 A.m2, at magnetic field of 28 mT. In addition, the morphology of the microrobot is characterized using Scanning Electron Microscopy images. The characterized parameters and morphology are used in the simulation of the locomotion mechanism of the microrobot to prove that its motion depends on breaking the time-reversal symmetry, rather than pulling with the magnetic field gradient. We experimentally demonstrate that the microrobot can controllably follow S-shaped, U-shaped, and square paths, and selectively target the cell mockups using image guidance and under the influence of the oscillating magnetic fields.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl fig1
Soft continuous microrobots with multiple intrinsic degrees of freedom

Palagi, S., Mark, A. G., Melde, K., Zeng, H., Parmeggiani, C., Martella, D., Wiersma, D. S., Fischer, P.

In 2016 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS), pages: 1-5, July 2016 (inproceedings)

Abstract
One of the main challenges in the development of microrobots, i.e. robots at the sub-millimeter scale, is the difficulty of adopting traditional solutions for power, control and, especially, actuation. As a result, most current microrobots are directly manipulated by external fields, and possess only a few passive degrees of freedom (DOFs). We have reported a strategy that enables embodiment, remote powering and control of a large number of DOFs in mobile soft microrobots. These consist of photo-responsive materials, such that the actuation of their soft continuous body can be selectively and dynamically controlled by structured light fields. Here we use finite-element modelling to evaluate the effective number of DOFs that are addressable in our microrobots. We also demonstrate that by this flexible approach different actuation patterns can be obtained, and thus different locomotion performances can be achieved within the very same microrobot. The reported results confirm the versatility of the proposed approach, which allows for easy application-specific optimization and online reconfiguration of the microrobot's behavior. Such versatility will enable advanced applications of robotics and automation at the micro scale.

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl image toc
Analysis of the magnetic torque on a tilted permanent magnet for drug delivery in capsule robots

Munoz, F., Alici, G., Zhou, H., Li, W., Sitti, M.

In Advanced Intelligent Mechatronics (AIM), 2016 IEEE International Conference on, pages: 1386-1391, July 2016 (inproceedings)

Abstract
In this paper, we present the analysis of the torque transmitted to a tilted permanent magnet that is to be embedded in a capsule robot to achieve targeted drug delivery. This analysis is carried out by using an analytical model and experimental results for a small cubic permanent magnet that is driven by an external magnetic system made of an array of arc-shaped permanent magnets (ASMs). Our experimental results, which are in agreement with the analytical results, show that the cubic permanent magnet can safely be actuated for inclinations lower than 75° without having to make positional adjustments in the external magnetic system. We have found that with further inclinations, the cubic permanent magnet to be embedded in a drug delivery mechanism may stall. When it stalls, the external magnetic system's position and orientation would have to be adjusted to actuate the cubic permanent magnet and the drug release mechanism. This analysis of the transmitted torque is helpful for the development of real-time control strategies for magnetically articulated devices.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl imagetoc
Magnetic propulsion of robotic sperms at low-Reynolds number

Khalil, I. S., Fatih Tabak, A., Klingner, A., Sitti, M.

Applied Physics Letters, 109(3):033701, AIP Publishing, July 2016 (article)

Abstract
We investigate the microswimming behaviour of robotic sperms in viscous fluids. These robotic sperms are fabricated from polystyrene dissolved in dimethyl formamide and iron-oxide nanoparticles. This composition allows the nanoparticles to be concentrated within the bead of the robotic sperm and provide magnetic dipole, whereas the flexibility of the ultra-thin tail enables flagellated locomotion using magnetic fields in millitesla range. We show that these robotic sperms have similar morphology and swimming behaviour to those of sperm cells. Moreover, we show experimentally that our robotic sperms swim controllably at an average speed of approximately one body length per second (around 125 μm s−1), and they are relatively faster than the microswimmers that depend on planar wave propulsion in low-Reynolds number fluids.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image
Active Nanorheology with Plasmonics

Jeong, H. H., Mark, A. G., Lee, T., Alarcon-Correa, M., Eslami, S., Qiu, T., Gibbs, J. G., Fischer, P.

Nano Letters, 16(8):4887-4894, July 2016 (article)

Abstract
Nanoplasmonic systems are valued for their strong optical response and their small size. Most plasmonic sensors and systems to date have been rigid and passive. However, rendering these structures dynamic opens new possibilities for applications. Here we demonstrate that dynamic plasmonic nanoparticles can be used as mechanical sensors to selectively probe the rheological properties of a fluid in situ at the nanoscale and in microscopic volumes. We fabricate chiral magneto-plasmonic nanocolloids that can be actuated by an external magnetic field, which in turn allows for the direct and fast modulation of their distinct optical response. The method is robust and allows nanorheological measurements with a mechanical sensitivity of similar to 0.1 cP, even in strongly absorbing fluids with an optical density of up to OD similar to 3 (similar to 0.1% light transmittance) and in the presence of scatterers (e.g., 50% v/v red blood cells).

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl marss2016
Wireless actuator based on ultrasonic bubble streaming

Qiu, T., Palagi, S., Mark, A. G., Melde, K., Fischer, P.

In 2016 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS), pages: 1-5, July 2016 (inproceedings)

Abstract
Miniaturized actuators are a key element for the manipulation and automation at small scales. Here, we propose a new miniaturized actuator, which consists of an array of micro gas bubbles immersed in a fluid. Under ultrasonic excitation, the oscillation of micro gas bubbles results in acoustic streaming and provides a propulsive force that drives the actuator. The actuator was fabricated by lithography and fluidic streaming was observed under ultrasound excitation. Theoretical modelling and numerical simulations were carried out to show that lowing the surface tension results in a larger amplitude of the bubble oscillation, and thus leads to a higher propulsive force. Experimental results also demonstrate that the propulsive force increases 3.5 times when the surface tension is lowered by adding a surfactant. An actuator with a 4×4 mm 2 surface area provides a driving force of about 0.46 mN, suggesting that it is possible to be used as a wireless actuator for small-scale robots and medical instruments.

pf

link (url) DOI [BibTex]

link (url) DOI [BibTex]


Thumb xl 0278364915583539
Six-degree-of-freedom magnetic actuation for wireless microrobotics

Diller, E., Giltinan, J., Lum, G. Z., Ye, Z., Sitti, M.

The International Journal of Robotics Research, 35(1-3):114-128, SAGE Publications Sage UK: London, England, June 2016 (article)

Abstract
Existing remotely actuated magnetic microrobots exhibit a maximum of only five-degree-of-freedom (DOF) actuation, as creation of a driving torque about the microrobot magnetization axis is not achievable. This lack of full orientation control limits the effectiveness of existing microrobots for precision tasks of object manipulation and orientation for advanced medical, biological and micromanufacturing applications. This paper presents a magnetic actuation method that allows remotely powered microrobots to achieve full six-DOF actuation by considering the case of a non-uniform magnetization profile within the microrobot body. This non-uniform magnetization allows for additional rigid-body torques to be induced from magnetic forces via a moment arm. A general analytical model presents the working principle for continuous and discrete magnetization profiles, which is applied to permanent or non-permanent (soft) magnet bodies. Several discrete-magnetization designs are also presented which possess reduced coupling between magnetic forces and induced rigid-body torques. Design guidelines are introduced which can be followed to ensure that a magnetic microrobot design is capable of six-DOF actuation. A simple permanent-magnet prototype is fabricated and used to quantitatively demonstrate the accuracy of the analytical model in a constrained-DOF environment and qualitatively for free motion in a viscous liquid three-dimensional environment. Results show that desired forces and torques can be created with high precision and limited parasitic actuation, allowing for full six-DOF actuation using limited feedback control

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image patent
System and method to magnetically actuate a capsule endoscopic robot for diagnosis and treatment

Sitti, M., Yim, S.

May 2016, US Patent 9,445,711 (patent)

Abstract
Present invention describes a swallowable device with a soft, compliant exterior, whose shape can be changed through the use of magnetic fields, and which can be locomoted in a rolling motion through magnetic control from the exterior of the patient. The present invention could be used for a variety of medical applications inside the GI tract including but not limited to drug delivery, biopsy, heat cauterization, pH sensing, biochemical sensing, micro-surgery, and active imaging.

pi

link (url) [BibTex]


Thumb xl ye et al 2016 advanced materials
Gallium Adhesion: Phase Change of Gallium Enables Highly Reversible and Switchable Adhesion (Adv. Mater. 25/2016)

Ye, Z., Lum, G. Z., Song, S., Rich, S., Sitti, M.

Advanced Materials, 28(25):5087-5087, May 2016 (article)

Abstract
Gallium exhibits highly reversible and switchable adhesion when it undergoes a solid–liquid phase transition. The robustness of gallium is notable as it exhibits strong performance on a wide range of smooth and rough surfaces, under both dry and wet conditions. Gallium may therefore find numerous applications in transfer printing, robotics, electronic packaging, and biomedicine.

pi

DOI [BibTex]


Thumb xl singh et al 2016 advanced healthcare materials
Patterned and Specific Attachment of Bacteria on Biohybrid Bacteria-Driven Microswimmers

Singh, A. V., Sitti, M.

Advanced Healthcare Materials, 5(18):2325-2331, May 2016 (article)

Abstract
A surface patterning technique and a specific and strong biotin–streptavidin bonding of bacteria on patterned surfaces are proposed to fabricate Janus particles that are propelled by the attached bacteria. Bacteria-driven Janus microswimmers with diameters larger than 3 μm show enhanced mean propulsion speed. Such microswimmers could be used for future applications such as targeted drug delivery and environmental remediation.

pi

DOI [BibTex]


Thumb xl pnas 2016 lum 1608193113 2
Shape-programmable magnetic soft matter

Lum, G. Z., Ye, Z., Dong, X., Marvi, H., Erin, O., Hu, W., Sitti, M.

Proceedings of the National Academy of Sciences, 113(41):E6007–E6015, National Acad Sciences, May 2016 (article)

Abstract
Shape-programmable matter is a class of active materials whose geometry can be controlled to potentially achieve mechanical functionalities beyond those of traditional machines. Among these materials, magnetically actuated matter is particularly promising for achieving complex time-varying shapes at small scale (overall dimensions smaller than 1 cm). However, previous work can only program these materials for limited applications, as they rely solely on human intuition to approximate the required magnetization profile and actuating magnetic fields for their materials. Here, we propose a universal programming methodology that can automatically generate the required magnetization profile and actuating fields for soft matter to achieve new time-varying shapes. The universality of the proposed method can therefore inspire a vast number of miniature soft devices that are critical in robotics, smart engineering surfaces and materials, and biomedical devices. Our proposed method includes theoretical formulations, computational strategies, and fabrication procedures for programming magnetic soft matter. The presented theory and computational method are universal for programming 2D or 3D time-varying shapes, whereas the fabrication technique is generic only for creating planar beams. Based on the proposed programming method, we created a jellyfish-like robot, a spermatozoid-like undulating swimmer, and an artificial cilium that could mimic the complex beating patterns of its biological counterpart.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl 07487340
Sperm-shaped magnetic microrobots: Fabrication using electrospinning, modeling, and characterization

Khalil, I. S., Tabak, A. F., Hosney, A., Mohamed, A., Klingner, A., Ghoneima, M., Sitti, M.

In Robotics and Automation (ICRA), 2016 IEEE International Conference on, pages: 1939-1944, May 2016 (inproceedings)

Abstract
We use electrospinning to fabricate sperm-shaped magnetic microrobots with a range of diameters from 50 μm to 500 μm. The variables of the electrospinning operation (voltage, concentration of the solution, dynamic viscosity, and distance between the syringe needle and collector) to achieve beading effect are determined. This beading effect allows us to fabricate microrobots with similar morphology to that of sperm cells. The bead and the ultra-fine fiber resemble the morphology of the head and tail of the sperm cell, respectively. We incorporate iron oxide nanoparticles to the head of the sperm-shaped microrobot to provide a magnetic dipole moment. This dipole enables directional control under the influence of external magnetic fields. We also apply weak (less than 2 mT) oscillating magnetic fields to exert a magnetic torque on the magnetic head, and generate planar flagellar waves and flagellated swim. The average speed of the sperm-shaped microrobot is calculated to be 0.5 body lengths per second and 1 body lengths per second at frequencies of 5 Hz and 10 Hz, respectively. We also develop a model of the microrobot using elastohydrodynamics approach and Timoshenko-Rayleigh beam theory, and find good agreement with the experimental results.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl toc imag
Auxetic Metamaterial Simplifies Soft Robot Design

Mark, A. G., Palagi, S., Qiu, T., Fischer, P.

In 2016 IEEE Int. Conf. on Robotics and Automation (ICRA), pages: 4951-4956, May 2016 (inproceedings)

Abstract
Soft materials are being adopted in robotics in order to facilitate biomedical applications and in order to achieve simpler and more capable robots. One route to simplification is to design the robot's body using `smart materials' that carry the burden of control and actuation. Metamaterials enable just such rational design of the material properties. Here we present a soft robot that exploits mechanical metamaterials for the intrinsic synchronization of two passive clutches which contact its travel surface. Doing so allows it to move through an enclosed passage with an inchworm motion propelled by a single actuator. Our soft robot consists of two 3D-printed metamaterials that implement auxetic and normal elastic properties. The design, fabrication and characterization of the metamaterials are described. In addition, a working soft robot is presented. Since the synchronization mechanism is a feature of the robot's material body, we believe that the proposed design will enable compliant and robust implementations that scale well with miniaturization.

pf

link (url) DOI [BibTex]

link (url) DOI [BibTex]


Thumb xl spie2016
Towards Photo-Induced Swimming: Actuation of Liquid Crystalline Elastomer in Water

cerretti, G., Martella, D., Zeng, H., Parmeggiani, C., Palagi, S., Mark, A. G., Melde, K., Qiu, T., Fischer, P., Wiersma, D.

In Proc. of SPIE 9738, pages: Laser 3D Manufacturing III, 97380T, April 2016 (inproceedings)

Abstract
Liquid Crystalline Elastomers (LCEs) are very promising smart materials that can be made sensitive to different external stimuli, such as heat, pH, humidity and light, by changing their chemical composition. In this paper we report the implementation of a nematically aligned LCE actuator able to undergo large light-induced deformations. We prove that this property is still present even when the actuator is submerged in fresh water. Thanks to the presence of azo-dye moieties, capable of going through a reversible trans-cis photo-isomerization, and by applying light with two different wavelengths we managed to control the bending of such actuator in the liquid environment. The reported results represent the first step towards swimming microdevices powered by light.

pf

link (url) DOI [BibTex]

link (url) DOI [BibTex]


Thumb xl inflateble robots
Inflated soft actuators with reversible stable deformations

Hines, L., Petersen, K., Sitti, M.

Advanced Materials, 28(19):3690-3696, March 2016 (article)

Abstract
Most soft robotic systems are currently dependent on bulky compressors or pumps. A soft actuation method is presented combining hyperelastic membranes and dielectric elastomer actuators to switch between stable deformations of sealed chambers. This method is capable of large repeatable deformations, and has a number of stable states proportional to the number of actuatable membranes in the chamber.

pi

DOI Project Page [BibTex]


Thumb xl publications toc
Chemotaxis of bio-hybrid multiple bacteria-driven microswimmers

Zhuang, J., Sitti, M.

Scientific reports, 6, pages: 32135, Nature Publishing Group, March 2016 (article)

Abstract
In this study, in a bio-hybrid microswimmer system driven by multiple Serratia marcescens bacteria, we quantify the chemotactic drift of a large number of microswimmers towards L-serine and elucidate the associated collective chemotaxis behavior by statistical analysis of over a thousand swimming trajectories of the microswimmers. The results show that the microswimmers have a strong heading preference for moving up the L-serine gradient, while their speed does not change considerably when moving up and down the gradient; therefore, the heading bias constitutes the major factor that produces the chemotactic drift. The heading direction of a microswimmer is found to be significantly more persistent when it moves up the L-serine gradient than when it travels down the gradient; this effect causes the apparent heading preference of the microswimmers and is the crucial reason that enables the seemingly cooperative chemotaxis of multiple bacteria on a microswimmer. In addition, we find that their chemotactic drift velocity increases superquadratically with their mean swimming speed, suggesting that chemotaxis of bio-hybrid microsystems can be enhanced by designing and building faster microswimmers. Such bio-hybrid microswimmers with chemotactic steering capability may find future applications in targeted drug delivery, bioengineering, and lab-on-a-chip devices.

pi

DOI Project Page [BibTex]

DOI Project Page [BibTex]


Thumb xl publications toc
Targeted drug delivery and imaging using mobile milli/microrobots: A promising future towards theranostic pharmaceutical design

Vikram Singh, A., Sitti, M.

Current Pharmaceutical Design, 22(11):1418-1428, Bentham Science Publishers, March 2016 (article)

Abstract
Miniature untethered medical robots have been receiving growing attention due to technological advances in microactuation, microsensors, and microfabrication and have significant potential to reduce the invasiveness and improve the accessibility of medical devices into unprecedented small spaces inside the human body. In this review, we discuss therapeutic and diagnostic applications of untethered medical microrobots. Wirelessly controlled milli/microrobots with integrated sensors are revolutionizing micromanipulation based medical interventions and are enabling doctors to perform minimally invasive procedures not possible before. 3D fabrication technologies enabling milli/microrobot fabrication at the single cell scale are empowering high-resolution visual imaging and in vivo manipulation capabilities. Swallowable millirobots and injectabale ocular microrobots allow the gastric ulcer imaging, and performance of vitreoretinal microsurgery at previously inaccessible ocular sites. Many invasive excision and incision based diagnostic biopsy, prostrate, and nephrolgical procedures can be performed minimally or almost noninvasively due to recent advancements in microrobotic technology. Advances in biohybrid microrobot systems are pushing microrobotic systems even smaller, using biological cells as on-board microactuators and microsensors using the chemical energy. Such microrobotic systems could be used for local targeted delivery of imaging contrast agents, drugs, genes, and mRNA, minimally invasive surgery, and cell micromanipulation in the near future.

pi

link (url) [BibTex]


Thumb xl toc image
Dispersion and shape engineered plasmonic nanosensors

Jeong, H. H., Mark, A. G., Alarcon-Correa, M., Kim, I., Oswald, P., Lee, T. C., Fischer, P.

Nature Communications, 7, pages: 11331, March 2016 (article)

Abstract
Biosensors based on the localized surface plasmon resonance (LSPR) of individual metallic nanoparticles promise to deliver modular, low-cost sensing with high-detection thresholds. However, they continue to suffer from relatively low sensitivity and figures of merit (FOMs). Herein we introduce the idea of sensitivity enhancement of LSPR sensors through engineering of the material dispersion function. Employing dispersion and shape engineering of chiral nanoparticles leads to remarkable refractive index sensitivities (1,091 nmRIU(-1) at lambda = 921 nm) and FOMs (>2,800 RIU-1). A key feature is that the polarization-dependent extinction of the nanoparticles is now characterized by rich spectral features, including bipolar peaks and nulls, suitable for tracking refractive index changes. This sensing modality offers strong optical contrast even in the presence of highly absorbing media, an important consideration for use in complex biological media with limited transmission. The technique is sensitive to surface-specific binding events which we demonstrate through biotin-avidin surface coupling.

pf

link (url) DOI [BibTex]


Thumb xl publications toc
Parallel microcracks-based ultrasensitive and highly stretchable strain sensors

Amjadi, M., Turan, M., Clementson, C. P., Sitti, M.

ACS Applied Materials \& Interfaces, 8(8):5618-5626, American Chemical Society, Febuary 2016 (article)

Abstract
There is an increasing demand for flexible, skin-attachable, and wearable strain sensors due to their various potential applications. However, achieving strain sensors with both high sensitivity and high stretchability is still a grand challenge. Here, we propose highly sensitive and stretchable strain sensors based on the reversible microcrack formation in composite thin films. Controllable parallel microcracks are generated in graphite thin films coated on elastomer films. Sensors made of graphite thin films with short microcracks possess high gauge factors (maximum value of 522.6) and stretchability (ε ≥ 50%), whereas sensors with long microcracks show ultrahigh sensitivity (maximum value of 11 344) with limited stretchability (ε ≤ 50%). We demonstrate the high performance strain sensing of our sensors in both small and large strain sensing applications such as human physiological activity recognition, human body large motion capturing, vibration detection, pressure sensing, and soft robotics.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl amjadi et al 2016 advanced functional materials
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review

Amjadi, M., Kyung, K., Park, I., Sitti, M.

Advanced Functional Materials, 26, pages: 1678-1698, Febuary 2016 (article)

Abstract
There is a growing demand for flexible and soft electronic devices. In particular, stretchable, skin-mountable, and wearable strain sensors are needed for several potential applications including personalized health-monitoring, human motion detection, human-machine interfaces, soft robotics, and so forth. This Feature Article presents recent advancements in the development of flexible and stretchable strain sensors. The article shows that highly stretchable strain sensors are successfully being developed by new mechanisms such as disconnection between overlapped nanomaterials, crack propagation in thin films, and tunneling effect, different from traditional strain sensing mechanisms. Strain sensing performances of recently reported strain sensors are comprehensively studied and discussed, showing that appropriate choice of composite structures as well as suitable interaction between functional nanomaterials and polymers are essential for the high performance strain sensing. Next, simulation results of piezoresistivity of stretchable strain sensors by computational models are reported. Finally, potential applications of flexible strain sensors are described. This survey reveals that flexible, skin-mountable, and wearable strain sensors have potential in diverse applications while several grand challenges have to be still overcome.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image patent
Remotely addressable magnetic composite micro-actuators

Sitti, M., Diller, E., Miyashita, S.

Febuary 2016, US Patent App. 15/018,008 (patent)

Abstract
The present invention describes methods to fabricate actuators that can be remotely controlled in an addressable manner, and methods to provide remote control such micro-actuators. The actuators are composites of two permanent magnet materials, one of which is has high coercivity, and the other of which switches magnetization direction by applied fields. By switching the second material's magnetization direction, the two magnets either work together or cancel each other, resulting in distinct “on” and “off” behavior of the devices. The device can be switched “on” or “off” remotely using a field pulse of short duration.

pi

[BibTex]

[BibTex]


Thumb xl toc image patent
Remotely addressable magnetic composite micro-actuators

Sitti, M., Diller, E., Miyashita, S.

Febuary 2016, US Patent 9,281,112 (patent)

Abstract
The present invention describes methods to fabricate actuators that can be remotely controlled in an addressable manner, and methods to provide remote control such micro-actuators. The actuators are composites of two permanent magnet materials, one of which is has high coercivity, and the other of which switches magnetization direction by applied fields. By switching the second material's magnetization direction, the two magnets either work together or cancel each other, resulting in distinct “on” and “off” behavior of the devices. The device can be switched “on” or “off” remotely using a field pulse of short duration.

pi

link (url) [BibTex]

link (url) [BibTex]


Thumb xl b 07384529
Size optimization of a magnetic system for drug delivery with capsule robots

Munoz, F., Alici, G., Li, W., Sitti, M.

IEEE Transactions on Magnetics, 52(5):1-11, IEEE, January 2016 (article)

Abstract
In this paper, we present a methodology for the size optimization of an external magnetic system made of arc-shaped permanent magnets (ASMs). This magnetic system is able to remotely actuate a drug-release module embedded in a prototype of a capsule robot. The optimization of the magnetic system is carried out by using an accurate analytical model that is valid for any arbitrary dimensions of the ASMs. By using this analytical model, we perform parametric studies and conduct a statistical analysis [analysis of variance (ANOVA)] to investigate efficient ways to distribute the volume of the ASMs so that the dimensions and volume of the magnetic system are minimized while optimal flux densities and magnetic torques are obtained to actuate the drug delivery system (DDS). The ANOVA results, at 5% significance level, indicate that changes in the angular width followed by changes in the length of the ASMs have the highest impact on the magnetic linkage. Furthermore, our experimental results, which are in agreement with the analytical results, show that the size optimization of the magnetic system is effective for the actuation of the DDS in capsule robots.

pi

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image
Magnetic Propulsion of Microswimmers with DNA-Based Flagellar Bundles

Maier, A. M., Weig, C., Oswald, P., Frey, E., Fischer, P., Liedl, T.

Nano Letters, 16(2):906-910, January 2016 (article)

Abstract
We show that DNA-based self-assembly can serve as a general and flexible tool to construct artificial flagella of several micrometers in length and only tens of nanometers in diameter. By attaching the DNA flagella to biocompatible magnetic microparticles, we provide a proof of concept demonstration of hybrid structures that, when rotated in an external magnetic field, propel by means of a flagellar bundle, similar to self-propelling peritrichous bacteria. Our theoretical analysis predicts that flagellar bundles that possess a length-dependent bending stiffness should exhibit a superior swimming speed compared to swimmers with a single appendage. The DNA self-assembly method permits the realization of these improved flagellar bundles in good agreement with our quantitative model. DNA flagella with well-controlled shape could fundamentally increase the functionality of fully biocompatible nanorobots and extend the scope and complexity of active materials.

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image patent
Method for encapsulating a nanostructure, coated nanostructure and use of a coated nanostructure

Jeong, H. H., Lee, T. C., Fischer, P.

Google Patents, 2016, WO Patent App. PCT/EP2016/056,377 (patent)

Abstract
The present invention relates to a method for encapsulating a nanostructure, the method comprising the steps of: -providing a substrate; -forming a plug composed of plug material at said substrate; -forming a nanostructure (on or) at said plug; -forming a shell composed of at least one shell material on external surfaces of the nanostructure, with the at least one shell material covering said nanostructure and at least some of the plug material,whereby the shell and the plug encapsulate the nanostructure. The invention further relates to a coated nanostructure and to the use of a coated nanostructure.

pf

link (url) [BibTex]

1998


Thumb xl toc image
Surface second-order nonlinear optical activity

Fischer, P., Buckingham, A.

JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 15(12):2951-2957, 1998 (article)

Abstract
Following the recent observation of a large second-harmonic intensity difference from a monolayer of chiral molecules with left and right circularly polarized light, the scattering theory is generalized and extended to predict linear and circular intensity differences for the more Versatile sum-frequency spectroscopy. Estimates indicate that intensity differences should be detectable for a typical experimental arrangement. The second-order nonlinear surface susceptibility tensor is given for different surface point groups in the electric dipole approximation; it is shown that nonlinear optical activity phenomena unambiguously probe molecular chirality only for molecular monolayers that are symmetric about the normal. Other surface symmetries can give rise to intensity differences from monolayers composed of achiral molecules. A water surface is predicted to show Linear and nonlinear optical activity in the presence of an electric field parallel to the surface. (C) 1998 Optical Society of America {[}S0740-3224(98)01311-3] OCIS codes: 190.0190, 190.4350, 240.6490.

pf

DOI [BibTex]

1998


DOI [BibTex]


Thumb xl toc image
Linear electro-optic effect in optically active liquids

Buckingham, A., Fischer, P.

CHEMICAL PHYSICS LETTERS, 297(3-4):239-246, 1998 (article)

Abstract
A linear effect of an electrostatic field F on the intensity of sum- and difference-frequency generation in a chiral liquid is predicted. It arises in the electric dipole approximation. The effect changes sign with the enantiomer and on reversing the direction of the electrostatic field. The sum-frequency generator chi(alpha beta gamma)((2)) (-omega(3);omega(1),omega(2)), where omega(3) = omega(1) + omega(2), and the electric field-induced sum-frequency generator chi(alpha beta gamma delta)((3))(-omega(3);omega(1),omega(2),0)F-delta interfere and their contributions to the scattering power can be distinguished. Encouraging predictions are given for a typical experimental arrangement. (C) 1998 Elsevier Science B.V. All rights reserved.

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image
Monolayers of hexadecyltrimethylammonium p-tosylate at the air-water interface. 1. Sum-frequency spectroscopy

Bell, G., Li, Z., Bain, C., Fischer, P., Duffy, D.

JOURNAL OF PHYSICAL CHEMISTRY B, 102(47):9461-9472, 1998 (article)

Abstract
Sum-frequency vibrational spectroscopy has been used to determine the structure of monolayers of the cationic surfactant, hexadecyltrimethylammonium p-tosylate (C(16)TA(+)Ts(-)), at the surface of water. Selective deuteration of the cation or the anion allowed the separate detection of sum-frequency spectra of the surfactant and of counterions that are bound to the monolayer. The p-tosylate ions an oriented with their methyl groups pointing away from the aqueous subphase and with the C-2 axis tilted, on average, by 30-40 degrees from the surface normal. The vibrational spectra of C(16)TA(+) indicate that the number of gauche defects in the monolayer does not change dramatically when bromide counterions are replaced by p-tosylate. The ends of the hydrocarbon chains of C16TA+ are, however, tilted much further from the surface normal in the presence of p-tosylate than in the presence of bromide. A quantitative analysis of the sum-frequency spectra requires a knowledge of the molecular hyperpolarizability tensor: the role of ab initio calculations and Raman spectroscopy in determining the components of this tensor is discussed.

pf

DOI [BibTex]

DOI [BibTex]


Thumb xl toc image
Ultraviolet resonance Raman study of drug binding in dihydrofolate reductase, gyrase, and catechol O-methyltransferase

Couling, V., Fischer, P., Klenerman, D., Huber, W.

BIOPHYSICAL JOURNAL, 75(2):1097-1106, 1998 (article)

Abstract
This paper presents a study of the use of ultraviolet resonance Raman (UVRR) spectroscopic methods as a means of elucidating aspects of drug-protein interactions. Some of the RR vibrational bands of the aromatic amino acids tyrosine and tryptophan are sensitive to the microenvironment, and the use of UV excitation radiation allows selective enhancement of the spectral features of the aromatic amino acids, enabling observation specifically of their change in microenvironment upon drug binding. The three drug-protein systems investigated in this study are dihydrofolate reductase with its inhibitor trimethoprim, gyrase with novobiocin, and catechol O-methyltransferase with dinitrocatechol. It is demonstrated that UVRR spectroscopy has adequate sensitivity to be a useful means of detecting drug-protein interactions in those systems for which the electronic absorption of the aromatic amino acids changes because of hydrogen bonding and/or possible dipole-dipole and dipole-polarizability interactions with the ligand.

pf

DOI [BibTex]

DOI [BibTex]


no image
Tele-nanorobotics using an atomic force microscope as a nanorobot and sensor

Sitti, M., Hashimoto, H.

Advanced Robotics, 13(4):417-436, Taylor & Francis, 1998 (article)

pi

[BibTex]

[BibTex]


no image
Nano tele-manipulation using virtual reality interface

Sitti, M., Horiguchi, S., Hashimoto, H.

In Industrial Electronics, 1998. Proceedings. ISIE’98. IEEE International Symposium on, 1, pages: 171-176, 1998 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Tele-nanorobotics using atomic force microscope

Sitti, M., Hashimoto, H.

In Intelligent Robots and Systems, 1998. Proceedings., 1998 IEEE/RSJ International Conference on, 3, pages: 1739-1746, 1998 (inproceedings)

pi

[BibTex]

[BibTex]


no image
2D micro particle assembly using atomic force microscope

Sitti, M., Hirahara, K., Hashimoto, H.

In Micromechatronics and Human Science, 1998. MHS’98. Proceedings of the 1998 International Symposium on, pages: 143-148, 1998 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Macro to nano tele-manipulation through nanoelectromechanical systems

Sitti, M., Hashimoto, H.

In Industrial Electronics Society, 1998. IECON’98. Proceedings of the 24th Annual Conference of the IEEE, 1, pages: 98-103, 1998 (inproceedings)

pi

[BibTex]

[BibTex]