Header logo is


2018


no image
Assessment Of Atypical Motor Development In Infants Through Toy-Stimulated Play And Center Of Pressure Analysis

Zhao, S., Mohan, M., Torres, W. O., Bogen, D. K., Shofer, F. S., Prosser, L., Loeb, H., Johnson, M. J.

In Proceedings of the Annual Rehabilitation Engineering and Assistive Technology Society of North America (RESNA) Conference, Arlington, USA, July 2018 (inproceedings)

Abstract
There is a need to identify measures and create systems to assess motor development at an early stage. Center of Pressure (CoP) is a quantifiable metric that has been used to investigate postural control in healthy young children [6], children with CP [7], and infants just beginning to sit [8]. It was found that infants born prematurely exhibit different patterns of CoP movement than infants born full-term when assessing development impairments relating to postural control [9]. Preterm infants exhibited greater CoP excursions but had greater variability in their movements than fullterm infants. Our solution, the Play And Neuro-Development Assessment (PANDA) Gym, is a sensorized environment that aims to provide early diagnosis of neuromotor disorder in infants and improve current screening processes by providing quantitative measures rather than subjective ones, and promoting natural play with the stimulus of toys. Previous studies have documented stages in motor development in infants [10, 11], and developmental delays could become more apparent through toy interactions. This study examines the sensitivity of the pressure-sensitive mat subsystem to detect differences in CoP movement patterns for preterm and fullterm infants less than 6 months of age, with varying risk levels. This study aims to distinguish between typical and atypical motor development through assessment of the CoP data of infants in a natural play environment, in conditions where movement may be further stimulated with the presence of a toy.

hi

link (url) [BibTex]

2018


link (url) [BibTex]


no image
Direct observations of sub-100 nm spin wave propagation in magnonic wave-guides

Träger, N., Gruszecki, P., Lisiecki, F., Förster, J., Weigand, M., Kuswik, P., Dubowik, J., Schütz, G., Krawczyk, M., Gräfe, J.

In 2018 IEEE International Magnetics Conference (INTERMAG 2018), IEEE, Singapore, 2018 (inproceedings)

mms

DOI [BibTex]

DOI [BibTex]


no image
Interpreting FORC diagrams beyond the Preisach model: an experimental permalloy micro array investigation

Gross, F., Ilse, S., Schütz, G., Gräfe, J., Goering, E.

In 2018 IEEE International Magnetics Conference (INTERMAG 2018), IEEE, Singapore, 2018 (inproceedings)

mms

DOI [BibTex]

DOI [BibTex]

2013


no image
Governance of Humanoid Robot Using Master Exoskeleton

Kumra, S., Mohan, M., Gupta, S., Vaswani, H.

In Proceedings of the IEEE International Symposium on Robotics (ISR), Seoul, South Korea, October 2013 (inproceedings)

Abstract
Dexto:Eka: is an adult-size humanoid robot being developed with the aim of achieving tele-presence. The paper sheds light on the control of this robot using a Master Exoskeleton which comprises of an Exo-Frame, a Control Column and a Graphical User Interface. It further illuminates the processes and algorithms that have been utilized to make an efficient system that would effectively emulate a tele-operator.

hi

DOI [BibTex]

2013


DOI [BibTex]


no image
Design and development part 2 of Dexto:Eka: - The humanoid robot

Kumra, S., Mohan, M., Gupta, S., Vaswani, H.

In Proceedings of the International Conference on Mechatronics and Automation (ICMA), Takamatsu, Japan, August 2013 (inproceedings)

Abstract
Through this paper, we elucidate the second phase of the design and development of the tele-operated humanoid robot Dexto:Eka:. Phase one comprised of the development of a 6 DoF left anthropomorphic arm and left exo-frame. Here, we illustrate the development of the right arm, right exo-frame, torso, backbone, human machine interface and omni-directional locomotion system. Dexto:Eka: will be able to communicate with a remote user through Wi-Fi. An exo-frame capacitates it to emulate human arms and its locomotion is controlled by joystick. A Graphical User Interface monitors and helps in controlling the system.

hi

DOI [BibTex]

DOI [BibTex]

2004


no image
High-speed dynamics of magnetization processes in hard magnetic particles and thin platelets

Goll, D., Kronmüller, H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 465-469, Laboratoire de Cristallographie/Laboratoire Louis Neel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

2004


[BibTex]


no image
High-speed dynamics of magnetization processes in hard magnetic particles and thin platelets

Goll, D., Kronmüller, H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 465-469, Laboratoire de Cristallographie/Laboratoire Louis Neel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Modern nanocrystalline/nanostructured hard magnetic materials

Kronmüller, H., Goll, D.

In 272-276, pages: e319-e320, Rome [Italy], 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Modern nanostructured high-temperature permanent magnets

Goll, D., Kronmüller, H., Stadelmaier, H. H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 578-583, Laboratoire de Cristallographie/Laboratoire Louis Néel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Imaging sub-ns spin dynamics in magnetic nanostructures with magnetic transmission X-ray microscopy

Fischer, P., Stoll, H., Puzic, A., Van Waeyenberge, B., Raabe, J., Haug, T., Denbeaux, G., Pearson, A., Höllinger, R., Back, C. H., Weiss, D., Schütz, G.

In Synchrotron Radiation Instrumentation, 705, pages: 1291-1294, AIP Conference Proceedings, American Institute of Physics, San Francisco, California (USA), 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Modern nanostructured high-temperature permanent magnets

Goll, D., Kronmüller, H., Stadelmaier, H. H.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 578-583, Laboratoire de Cristallographie/Laboratoire Louis Néel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Existence of transient temperature spike induced by SHI: evidence by ion beam analysis

Avasthi, D. K., Ghosh, S., Srivastava, S. K., Assmann, W.

In 219-220, pages: 206-214, Albuquerque, NM [USA], 2004 (inproceedings)

mms

[BibTex]

[BibTex]


no image
Hard magnetic hollow nanospheres

Goll, D., Berkowitz, A. E., Bertram, H. N.

In Proceedings of the 18th International Workshop on Rare-Earth Magnets and their Applications, pages: 704-707, Laboratoire de Cristallographie/Laboratoire Louis Neel, CNRS, Grenoble, 2004 (inproceedings)

mms

[BibTex]

[BibTex]